Kìm kẹp dòng Kew 8129 dùng cho đồng hồ Kyoritsu Kew 5010, Kew 5020, Kew 6305, Kew 6315
KEW 8129
-

-

Ø150mm
■KEW8129-01 (for 1ch)
■KEW8129-02 (for 2ch)
■KEW8129-03 (for 3ch)
• Flexible for various test fields
• Can measure AC current up to 3000A
• Flexible and light weight by the air core coil used at the sensor part
• Measurable conductor size: max Φ150mm
• Designed to meet the international safety standard IEC 61010-1 CAT III 600V
* When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.
Conductor size |
max.Ø150mm |
Rated current |
300/1000/3000A |
Output voltage |
300A Range : AC500mV/AC300A (1.67mV/A)
1000A Range : AC500mV/AC1000A (0.5mV/A)
3000A Range : AC500mV/AC3000A (0.167mV/A) |
Accuracy |
±1.0%rdg (45 - 65Hz) |
Phase shift |
within ±1° |
Cable length |
Sensor part : approx. 2m
Output cable : approx. 1m |
Output connector |
MINI DIN 6PIN |
Output impedance |
100Ω or less |
Applicable standards |
IEC 61010-1, IEC 61010-2-032 CAT III 600V Pollution degree2,
IEC 61326 |
Operating temperature & humidity range |
0 - 50ºC, relative humidity 85% or less (no condensation) |
Dimensions |
111(L) x 61(W) x 43(D) mm (except for protrusions) |
Weight |
8129-01 (for 1ch) Approx. 410g
8129-02 (for 2ch) Approx. 680g
8129-03 (for 3ch) Approx. 950g |
Included Accessories |
8129-01 (for 1ch) Instruction Manual, 7199 (Output Cable) x1, 9137 (Carrying Case)
8129-02 (for 2ch) Instruction Manual, 7199 (Output Cable) x2, 9137 (Carrying Case)
8129-03 (for 3ch)Instruction Manual, 7199 (Output Cable) x3, 9137 (Carrying Case) |
Accessories/Optional Accessories /Related Products
-
Instruction Manual
-
Applicable model list